Savannah, GA

Fumigant

Phosphine (PH₃)

Volume

184,000 ft³

Exposure

72 h

Clearance

< 0.3 ppm

Fumigator in full protective suit indoors

Scope

A bonded warehouse holding imported dried goods found live stored-product beetles during a routine inspection. Stock could not be moved before the next shipment.

Treatment

The building was sealed, placarded and treated with phosphine over a 72-hour exposure. Concentration was logged every six hours from four monitoring lines.

Result

Clearance below 0.3 ppm was recorded at all points on day four. No live insects were found at the follow-up inspection two weeks later.

Release sign-off

Space released only after a clearance reading below the re-entry limit, recorded by a licensed applicator.